INSULATION:

Fiberglass shall be as outlined in the North American Insulation Manufacturing Association (NAIMA 202-96) specification, or equal, with an R-value of----------when not compressed. The fiberglass shall be faced with----A----, as specified below, on one side. The composite of fiberglass and facing shall have surface burning characteristics not to exceed 25 flame spread and 50 smoke developed when tested in accordance with Underwriters Laboratories 723 test method or ASTM E84 test method.

FACING:

Facing shall be composed of B , C reinforcing layer, and D . The resulting facing shall have a water vapor transmission rate of E US perm (ASTM E96, Procedure A), a beach puncture of F scale units and a mullen burst of G psi. Tensile strength shall be H in the machine direction and I in the cross-machine direction.

 
A
PRODUCT
B
EXPOSED SURFACE
C
REINFORCED LAYER
D
BACKING LAYER
E
PERM
F
BEACH
G
MULLEN
H
MD TENSILE
I
XD
TENSILE

MOST POPULAR FACINGS

WMP-VR .0015" White Polypropylene Film 4 x 5  Tri-directional Scrim 11#  Kraft Paper .09 125 60 40# 30#
WMP-10 .0015" White Metallized Polypropylene Film 5 x 5  Tri-directional Scrim 14#  Kraft Paper .02 125 65 40# 35#
WMP-50 .0015" White Polypropylene Film 4 x 5  Tri-directional Scrim .0005" Metallized Polyester Film .02 125 100 55# 50#

SPECIALTY FACINGS

R-3035 HD .0003" Aluminum Foil 5 x 5  Tri-directional Scrim 30#  Kraft Paper .02 85 60 55# 35#
WMP-30 .0015" White Metallized Polypropylene Film 5 x 5  Tri-directional Scrim 30#  Kraft Paper .02 105 70 55# 40#
WMP-F .0015" White Polypropylene Film 4 x 4 Bi-directional Scrim .0003" Aluminum Foil .02 130 90 45# 45#
VRP HD Flexible White Vinyl 4 x 4 Bi-directional Scrim .0005" Metallized Polyester Film .02 150 85 40# 30#
VSF HD Rigid White Vinyl 4 x 4 Bi-directional Scrim .0005" Aluminum Foil .02 50 80 45# 30#
ARENASHIELD .0003" Aluminum Foil N/A Fiberglass/Polyester Blend Fabric .02 550 250 195# 150#
GYMGUARD .0015" White Metallized Polypropylene Film N/A Fiberglass/Polyester Blend Fabric .02 650 250 195# 150#
 
Mullen  - a measure of the force required for a blunt object to rupture the facing (reported in lbs./sq. inch).
Beach  - a measure of the energy required for a sharp object to puncture the facing (reported in beach units).
Tensile - resistance to breaking while being pulled (measured in lbs./inch of width).

Available Widths: Metal Building

 

PRODUCT

STANDARD WIDTHS
(inches)

WT / MSF
(pounds)

STANDARD WIDTHS
(meters)

WT / M²
(grams)

WMP-VR 42, 54, 66, 78, 84, 90

17

1.07, 1.37, 1.68, 1.98, 2.13, 2.29      

83

WMP-10 42, 54, 66, 78, 84, 90

19

1.07, 1.37, 1.68, 1.98, 2.13, 2.29

93

WMP-30 42, 54, 66, 78, 84, 90

29

1.07, 1.37, 1.68, 1.98, 2.13, 2.29

142

WMP-50 42, 54, 66, 78, 84

25

1.07, 1.37, 1.68, 1.98, 2.13

121

WMP-F 42, 54, 66, 78, 84

17

1.07, 1.37, 1.68, 1.98, 2.13

83

VRP HD 42, 54, 66, 78

30

1.07, 1.37, 1.68, 1.98

147

VSF HD 42, 54

29

1.07, 1.10, 1.32, 1.37

142

ARENASHIELD 54, 78

40

1.37, 1.98

195

GYMGUARD 54, 78

34

1.37, 1.98

166

R-3035 HD 42, 54, 66, 78, 84, 90    

24

1.07, 1.37, 1.68, 1.98, 2.13, 2.29

117

 
  

Quonset Insulation

   

WMP-50

POLYPROPYLENE / SCRIM / CORE / METALLIZED POLYESTER

Meets ASTM C1136,Typo I, H,lM, IV

Tentative Specification

FACING COMPOSITION DESCRIPTION VALUES (ENGLISH) VALUES (METRIC)
White Film Polypropylene 0.0015 inch 38.1 micron
Adhesive Flame Resistant  
Reinforcing Tri-directional 5 / inch(MD) 20 /100 mm (MD)
  Fiberglass/Polyester 5 / inch (XD) 20 /100 mm (XD)
Core Proprietary 30 lbs / 3000 ft2 49gm/m*
Adhesive Polymeric  
Rim Metallized Polyester 0.0005 inch 12.7 micron
PHYSICAL PROPERTIES TEST METHOD VALUES (ENGLISH) VALUES (METRIC)
Basis Weight Scale 32 lbs/1000 ft2 156gm/rrr*
Permeance (WVTR) ASTME96 0.02 perm 1.15ng/Ns
  Procedure A (grains/hrfPin Hg)  
Bursting Strength ASTM D774 120 psi 8.4 kg/cm2
Puncture Resistance ASTMC1136 125 beach units 3.7 Joules
Tensile Strength ASTM C1136 65 lbs/inch width (MD) 11.4kn/m(MD)
  60 lbs/inch width (XD) 10.5kn/m(XD)
CaEiper / Thickness Micrometer 0.010 inch 254 micron
Accelerated Aging 30 Days @ No Corrosion No Corrosion
  95% RH, 120°F(49°C) No Determination No Defamination
Low Temperature Resistance ASTM D1790 Remains Flexible Remains Flexible
  -40*F (-40°C) No Delamination No Delamination
High Temperature Resistance 4 hours @ Remains Flexible Remains Flexible
  240*F(116°C} No Delamination No Deiamination
Water Immersion 24 hours @ 73°F (23CC) No Delamination No Delamination
Mold Resistance ASTMC865/C1338 No Growth No Growth
Dimensional Stability ASTMD1204 0.25% 0.25%
Light Reflectance ASTM C523 85% 85%
       
FIRE TESTING      
  UL-723/ASTME84 CAN ULC-S102M
  Flame                     Smoke Flame Smoke
  Spread                 Developed Spread Developed
Polypropylene Exposed 5                            30 5 30
Polyester Exposed 5                            20 5 20
Physical Properties based upon statistical averages. Weight / Thickness +1- 10%
 
  
   
  GYMGUARD  
POLYPROPYLENE / FIBERGLASS-POLYESTER BLEND
FABRIC
FACING COMPOSITION DESCRIPTION VALUES (ENGLISH) VALUES (METRIC)
White Rim Metallized Polypropylene 0.0015 inch 38.1 micron
Adhesive Flame Resistant    
Fabric Fiberglass/Polyester Blend 75 lbs / 3000 W 122 gm / m2
       
PHYSICAL PROPERTIES TEST METHOD VALUES (ENGLISH)  VALUES (METRIC)
Basis Weight Scale 34 lbs / 1000 ft2 166 gm / m2
Permeance (WVTR) ASTM E96 0.02 perm 1.15 ng / N,s
  Procedure A (grainslhrftzin Hg)  
Bursting Strength ASTM D774 250 psi 17.6 kg / cm2
Puncture Resistance ASTM 01136 650 beach units 19.4 Joules
Tensile Strength ASTM 01136 195 IbsJinch width(MD) 34.1 kn / m (MD)
    150 lbs/inch width(XD) 26.3 kn / m (XD)
Caliper / Thickness Micrometer 0.007 inch 178 micron
Accelerated Aging 30 Days 0 No Corrosion No Corrosion
  95°/a RH, 120°F (49°C) No Delamination No Delamination
Low Temperature Resistance ASTM D1790 Remains Flexible Remains Flexible
  -40°F (-40°C) No Delamination No Delamination
High Temperature Resistance 4 hours Remains Flexible Remains Flexible
  240°F (116°C) No Delamination No Delamination
Water immersion 24 hours 0 73°F (23°C) No Delamination No Delamination
Mold Resistance ASTM 0665 No Growth No Growth
Dimensional Stability ASTM D1204 0.25% 0.25°!0
Light Reflectance ASTM C523 85% 85°/d
       
FIRE TESTING      
  UL-723 CAN ULC-S1 02M
  Flame Smoke Flame Smoke
  Spread Developed Spread Developed
Film Exposed -30 5 30
Fabric Exposed 540 5 40
                    Physical Properties based upon statistical
                   averages, Weight I Thickness +/- 10%
 
  

Avoid future moisture problems by using a low perm facing:


Reduces the moisture entering the fiberglass insulation
Enables the insulation to perform as designed
Reduces the likelihood of water problems

 

 

The word "Perm" is used to quantify the rate of water vapor transfer through the facing into the fiberglass and onto the metal skin of the building. There are three basic perm levels offered by the facing suppliers: .02, .09 and 1.0. Lower perm facings reduce the amount of moisture entering the fiberglass which helps to save energy, reduce condensation and avoid future moisture related problems. Theoretically*, in a 50,000 square foot building, a .02 perm facing will only allow 1 gallon of water to pass through the facing in one week. This compares to 5 gallons for a facing with a .09 perm, and 50 gallons for a facing with a 1.0 perm rating.

*Test Conditions: ASTM E96 Procedure A - 73° F (23°C) and 50 % RH on one side of the vapor retarder, and 73° F (23°C) and 0 % RH on the other side
.